Tag Archives: Twisted Pair Cable

Ethernet Cable Types – Cat5e, Cat6, Cat6a, and Cat7

FacebookTwitterGoogle+LinkedInRedditTumblrShare

When selecting the appropriate Category of cable to support your network, note that there are different grades within each Category. A higher grade cable with the proper installation will allow for a higher margin of error, ensuring top performance today and an extra buffer to support future technology. Properly selecting Cat5e, Cat6, Cat6a, Cat7 solutions will optimally support current and future network speed requirements. But which one should you choose? This text will give you some guidance.

The Cat5e has Replaced the Cat5 Ethernet Cable

cat5e ethernet cableCat5 cable can support 10/100 Ethernet. That is, Ethernet and Fast Ethernet. However, Cat 5e cable can support Ethernet, Fast Ethernet, and Gigabit Ethernet. Cat5e Cable is completely backwards compatible, and can be used in any application in which you would normally use Cat 5 cable. Crosstalk is the electrical interference that results when one wire’s signal affects another wire’s signal. Cat5e cable has been improved over Cat5 cable in this respect, and cross talk has been greatly reduced. We all know that bandwidth is directly related to network support. The greater the bandwidth, the greater the information-carrying capacity in a given period of time. Cat5e cable is rated at 100 MHz, and it is this increased bandwidth (compared to Cat5 cable) that allows it to support Gigabit Ethernet. Since 1G is widely used today, the Cat5e has gradually replaced the Cat5.

Use Cat5e or Cat 6 Ethernet Cable?

cat6 UTP patch cableCat6 is a standardized cable for Gigabit Ethernet and other network physical layers that is backward compatible with the Cat5/5e and Cat3 cable standards. Compared with Cat5 and Cat5e,  Cat6 features more stringent specifications for crosstalk and system noise. The cable standard provides performance of up to 250 MHz and is suitable for 10BASE-T, 100BASE-TX (Fast Ethernet), 1000BASE-T/1000BASE-TX (Gigabit Ethernet). We may notice that both Cat5e and Cat6 can support Gigabit Ethernet, however, Cat6 is certified for Gigabit networking and will perform better over longer distances. So choosing the Cat6 cable will be more stable to meet the Gigabit needs. But one thing you should keep in mind is that your network is only as fast as your slowest component, so unless every piece of your network (routers, cables, etc.) supports Gigabit Ethernet, you will not be able to reach those speeds.

Differences between Cat6 and Cat6a Ethernet Cable

cat6a stp cableThe latest standard from the TIA for enhanced performance standards for twisted pair cable systems was defined in February 2009 in ANSI/TIA-568-C.1. According to this standard, Cat6a is also called Augmented Cat6, which is 10-Gigabit Ethernet over copper proposal to the Cat6 standard. Category 6a performs at improved specifications, in particular in the area of alien crosstalk as compared to Cat6, which exhibited high alien noise in high frequencies. Cat6 specifies cable operating at minimum frequency of 500 MHz—twice that of Cat 6, for both shielded and unshielded. It can support future 10 Gb/s applications up to the maximum distance of 100 meters on a 4-connector channel. Compared with the Cat6, Cat6a is more effective and flexible. As 10G is more and more widely used, Cat6a will become more and more popular.

Cat7 Will be the Ethernet Cable of Choice

cat7 network patch cableCat7 cables are designed to support much higher frequency signals than Cat5e and Cat6. This allows Cat7 cabling to carry a larger amount of information. Cat7 cable is also able to better protect the signals traveling over the cable. The shielding as well as the tighter twists of the pairs in Cat7 cable lessens the effects of crosstalk and EMI. Cat7 cable is commonly terminated using a GG45 connector, which is a connector that it backwards compatible with the 8p8c RJ45 connectors used on Cat6 or Cat5e cable. The GG45 connector has four additional conductors that provide support for frequencies of up to 600MHz. The higher frequencies allow Cat 7 cable to support 10-Gigabit Ethernet. Currently, Cat7 is not widely adopted. Cat5e and Cat6 solutions sufficiently support the bandwidth requirements of today’s data centers, networks, and end users. Using Cat7 for a connection to a desktop would be unnecessary because the bandwidth would not be utilized. It may also be an unnecessary expense for many data center applications for the same reason. However, as technology advances and requirements increase, Cat7 cable will become more relevant in the data center and desktop connections.

Ethernet Cable Comparison

Some specifications for Cat5, Cat6, Cat7 are introduced above, then I will show you a table. From the table below, you can see their differences more clearly:

cat5 cat5e cat6 cat6a cat7 cat7a

Learn more about Catx Cabing  Jargon from Here: http://www.fs.com/category-5–5e-cat-6-cat7-cabling-jargon-aid-337.html

Related Article: Quick View of Ethernet Cables Cat5, Cat5e and Cat6

Why Choose the Shielded Cabling System

Shielded VS. Unshielded Cabling

In copper structured cabling system at all levels, there are two main technical types: Shielded and Unshielded cabling systems. Both types have been in existence since the earliest cabling standards were defined. While shielded cabling became popular from the outset in countries like Germany, Austria,Switzerland and France, U/UTP was quickly adopted in the rest of the world. Although both systems work fine at 1 Gigabit Ethernet data rates, shielded systems can demonstrate superior performanceat higher data rates such as 10G due to their ability to reliably support higher frequency transmission.

Cable structure

What Is the Function of Shielded?

F/UTP

F/UTP cable shielding structure is four pairs of wires in the data cable outside the contractor a layer of aluminum foil shielded, this layer of shielding can be reduced to a great extent the total package:

This is the root of the signal transmission cable radiated interference signals on the impact of adjacent data cable (for example: the same bundle of cables in the adjacent data cable).Interference from other data cable or other interference source signal for this cable.For a high quality data transmission system, which is significant in two kinds of effects. If the external interference signal is strong enough it will happen with the normal transmission signal stack a plus, resulting in reduced transmission performance even the entire system can not work properly.

S/FTP

S/FTP structure in addition to the total package of braided foil shield, twisted pair cable are respectively in each pair with a layer of aluminum foil shield to protect the transmission signal does not interfere with each other, so near-end crosstalk attenuation (NEXT)performance dramatically. NEXT better performance means higher SNR and better transmission quality and faster system output. S/FTP shielded cables NEXT excellent structural performance of other cables (such as non-shielded U/UTP) can not be compared, therefore, ISO11801 on the Cat 7 (600MHz) and Cat 7a  (1000MHz) only provides the S/FTP cable structure, U/UTP cannot meet.

10GBase-T Makes Data Cable Face New Problem: Alien Crosstalk

2006 Copper Gigabit Ethernet applications published the proposed new standard transport protocols 10GBASE-T. Compared to 1000Base-T, its transmission rate increased 10 times. 1000BASE-T copper cabling required parameters (Attenuation, NEXT, Return Loss, etc.) the bandwidth required to reach 1-100MHz, with UTP Cat 5e (Class D) cabling system to meet requirements. 10GBASE-T cabling channel requirements of all component parameters have to be up to 500MHz bandwidth, which requires copper to reach at least Cat.6A (Class Ea) or higher level.

Along with the development of 10GBASE-T, external noise problems become more evident, resulting in a specification for external noise to be used to assess in the same bundle of cables, the interaction between different cables. This is what we call Alien Crosstalk. Alien Crosstalk will increase with the increase of frequency. Worse, 10GBASE-T confronted with external noise, will not be able to “adaptive” to lower the rate at which the network may be subsequently face paralysis. Therefore, to support 10GBASE-T cabling system application, the ability to resist alien crosstalk is vital.

Since 10GBASE-T high transmission frequencies and complex coding method is very sensitive to the external noise. Shielding system excellent coupling atttenuation performance makes it naturally have to resist alien crosstalk.The unshielded system against alien crosstalk is usually only on the performance of 0dB.Shielding system in the design is completely satisfy the application of 10G.

The Installation of 10GBase-T: U/UTP VS. FTP 80a

Unshielded System

As far as possible away from power cable during installationDifferent applications (1Gb/s and 10Gb/s) in the same pipeline transmission will cause the external crosstalk.

Shielding System

With the power cable can be reduced separation distanceAllow different applications (1 Gb / s and 10 Gb / s) in the same pipeline transmissionDoes not need additional external crosstalk test field

The Separation Distance Between the Data Cable and Power Cable

In EN50174 standard defines the content of different coupling attenuation value level of data cable, respectively, from A (low coupling attenuation, worse) to D (high coupling attenuation, good) four levels.

Classification of information technology cables

Screened Unscreened Coaxial/twinaxial Segregation classification
Coupling attenuation at 30 Mhz to 100 Mhz TCL at 30 MHz to 100 MHz Screening attenuation at 30 MHz to 100 MHz
>= 80dB >= 70 -10xlg(f) dB >= 85dB d
>= 55dB >= 60 -10xlg(f) dB >= 55 dB c
>= 40 dB >= 50 -10xlg(f)dB >= 40 dB b
< 40 dB <50 -10xlg(f) dB < 40 dB a

Installers need to know which cable separated levels to determine the choice of the data requirements of the standard cable with power cable between the minimum separation distance. Data cable coupling attenuation higher the value and power cables minimum separation distance between the smaller. Please refer to the following three examples, screenshots from Nexans Toolkit.

U/UTP

Example 1: U/UTP (Class B – Coupling Attenuation >/= 40dB) -> 225mm

F/UTP

Example 2: F/UTP (Class C – Coupling Attenuation >/= 55dB)-> 114mm

S/FTP

Example 3: S/FTP (Class D – Coupling Attenuation >/= 80dB)-> 24mm

Relative to the shielded cable, the unshielded (U/UTP) separation distance between cable and power cable to further. In the implementation of the project, if need the data cable and power cable isolation far distance, we need a bigger size pipe/bridge, or even additional bridge, doing this will no doubt have higher cost, sometimes limited to the bridge installation space. To make matters worse, these additional requirements often neglected or ignored, resulting in network system is the key point of interference.

Grounding

For shielded, unshielded systems and fiber optic cable, all need to implement protective grounding. Because of the need to consider personal and equipment safety, therefore no matter adopt what kind of cabling system, the metal part of the system must be grounded. For the shielding system, also need to implement the functional ground. Grounded shielding system functions with respect to the implementation of non-shielded systems only difference is that when you install the module connector and the cable shielding mask area area connected.

Conclusion

Shielding system relative to the unshielded system has been greatly improved EMC performance. For Gigabit Ethernet applications, shielding against external interference effects is essential, and shielded cabling system had to meet the standards in the design of anti-alien crosstalk (A-XT) requirements, can effectively prevent the cable from the adjacent between the external crosstalk. Shielded cabling system, properly grounded at both ends of the case, to resist external interference characteristics superior to unshielded system 40dB.

How To Purchase Twisted Pair Cable

In its simplest form, twisted-pair cable consists of two insulated strands of copper wire twisted around each other. There are two types of twisted-pair cable: unshielded twisted-pair (UTP) and shielded twisted-pair (STP) cable. A number of twisted-pair wires are often grouped together and enclosed in a protective sheath to form a cable. The total number of pairs in a cable varies. The twisting cancels out electrical noise from adjacent pairs and from other sources such as motors, relays, and transformers.

Category 5e or Category 6

Currently there is a great deal of confusion among Ethernet cable buyers concerning whether to purchase Cat5e, or to use Cat6. Most of this confusion comes from a misunderstanding by the buyer that buying Cat6 cable will give them an “all gigabit” network. This is not the case. Unless every single component in the network is gigabit rated, then you will never have a gigabit network, because your network will always run at the speed of your slowest device.

Cat5e cable of good quality can run near or at gigabit speeds, it just cannot be “certified” for this use. By comparison, Cat6 is designed especially for gigabit use, and is certified to operate at said speed. It becomes a matter of whether or not you want to pay all that extra money, for little or no noticeable improvement in the performance of you network.

In most cases, it makes more sense to go with Cat5e. It is for this reason that most of your new installations in the private sector are going with Cat5e. It is more economical, performs well, and is readily available in many colors. Many IT professionals when asked about why they specified Cat6 for a specific job, often responded stated that they “wanted the best they could get.” This is the line of thought behind many purchases of cable.

The average consumer often times is not aware that there is no real benefit to them to use Cat6, so they let someone talk them in to buying it. Fiberstore is committed to helping people make good decisions about cable purchases and we are always standing by to help you.

Fs twisted-pair-cable.jpg

How to Buy Twisted Pair Cable

Following are some advice you can take when choose a twisted pair cable for your network.

See Packing and Printing Quality

Carefully check the cable box to see whether packing is in good conditions. The packaging of fake cable is usually very poor, so the quality of the external packaging can determine the user’s first feeling. However, good quality cables are usually perfectly packaged. And many manufacturers still paste anti-fake label on the product packaging.

See Identifications on Cable’s Outer Layer

Twisted pair cable insulation outer layer shall be printed with the words such as manufacturers, place of origin, performance standards, product categories (Cat5e Ca6t, etc.) and cable length identification.

See Twisting Density

In order to reduce signal interference, each line pairs of the twisted pair cable are twisted in a counterclockwise direction to each other and the different line pairs of the same twisted pair cable also has different twisting density. If the twisting density does not meet the technical requirements, serious near-end crosstalk may appear due to the mismatch of the cable resistance, which will shorten transmission distance and reduce the transmission rate. Don’t choose twisted pair cables whose twisting density is incompetent.

See Cable Colors

After peeling the outer layer of twisted pair cable, you can see each pair of wires in a twisted-pair cable is one of four colors: orange, green, blue, or brown. The two wires that make up each pair are complementary. It should be noted that these colors are not dyed on the cable. Don’t choose cables whose color is not clear.

See Flame Retardants Cases

In order to avoid cable’s burning and damage caused by high temperature or fire, the outer layer of the twisted pair cable should have a very good tensile property and flame retardant property. The outer layer of a good twisted pair cable may be gradually melted and misshapen, but won’t burn itself.

Touch the Cable’s Outer Layer

In most cases, we can make an initial judgment by touching the outer layer of twisted pair cable. In order to save cost, bad cable usually uses terrible wire materials. So when we touch it, we may feel sticky and coarsened. However, a good twisted pair cable may feel smooth. Besides, considering that the cable may need to be curved, good cables usually have excellent extensibility. Therefore, good cables may feel full.

Conclusion

Taking the future applications into consideration, we should install the most advanced cabling products, because the cable is often difficult to re-install and replace. Then, you should use cat6 cables instead of cat 5e cable. Though cat 6 cable is a little expensive than cat 5e cable, in order to reduce cost for network upgrade in the future, cat 6 cables are still worth considering.